Global Switch Amsterdam East Brochure

TECHNICAL SPECIFICATION Location – The data centre is located 2km from the financial district and city centre – A local Metro station is immediately outside the main gate – Schiphol International Airport is 10 minutes away by car Building Overview – Global Switch has a long term ground lease with automatic renewal rights – Purpose built – Will exceed Tier III operational performance – 32,000 sq m of gross space – 2 data floors – Flexible IT space with ability to create bespoke environments as required Main Structural Features – Structural steel frame with reinforced concrete floors and metal faced cladding – 6m slab to slab height – No raised floor – Minimum from finish floor: 3.9m clear height to underside of deepest beam

Critical Environments Management – Experienced 24x7x365 facilities management team – Environment (thermal conditions) monitored 24x7x365 – All Building Management Systems (BMS) monitored 24x7x365 – Comprehensive energy metering systems – Internationally recognised critical environments programme

Connectivity – Carrier Neutral – Network dense with access to multiple global and regional carriers and Internet service providers offering Dark Fibre, Wavelength, Ethernet, MPLS, VPLS, IP Transit, Peering, CDN, Storage, Virtualised Services (SDN), Voice and Mobile Services – Access to multiple cloud services through leading public, private and hybrid cloud solution providers – 3 diverse MMRs servicing the campus – 3 diverse Building Entry Points servicing the campus – Diverse cable routes and pathways – Campus fibre system interconnecting Amsterdam East to Amsterdam West – Roof space availability for satellite and antennae equipment – AMS-IX, NL-IX, GE-CIX, NetIX Communications and Speed-IX present Fire Detection and Suppression – Fully addressable fire detection system in all areas – Aspirated early warning smoke detection system (monitored 24x7x365) – Gas suppression system in technical areas

– Mechanical systems backed up by standby generators with N+1 redundancy – Fully diverse power distribution to technical areas – On-site fuel storage to support 24 hours at full load with 24x7x365 fuel delivery – Offering 2,000 W/m 2 as standard, with higher power density solutions fully supported Cooling – 35MW of cooling provision – Minimum N+2 resilience on all systems – Chiller Assist free-cooling – Fan wall units control temperature and humidity in technical space within the recommended range of ASHRAE TC9.9 – Diverse distribution pipework throughout Security – Operations Centre manned 24x7x365 – Security guard patrols 24x7x365 – Continuous CCTV surveillance of external and internal areas – CCTV records kept for 31 days – Comprehensive intruder detection and alarms to all areas – Perimeter Intrusion Detection system (PIDs) – Strict access control procedures to ISO 27001 – Access control using proximity card readers and biometric systems – Physical access via mantrap – Secure managed delivery and loading area available 24x7x365

Other Services – Cross connects – Customer reports – Deliveries and storage – Design and build – Fit out – On-site facilities – Remote hands – Technical cleaning – Waste disposal

Certifications – ISO 9001, 14001, 27001, 45001, 50001 – ISAE 3402 – AMS-IX – PCI DSS Compliant

– Floor loading of 15kN/m – 2 goods lifts (4 tonnes)

Power – 50kV utility supply – Utility power supply capacity of 40MVA – Technical (IT) Power supplied by on-site Static UPS N+1 redundancy

Technical specification, which is subject to change, relates to the completion of all stages of Global Switch Amsterdam East